The Loopback Test of the RS232 Serial to Ethernet Converter USR-TCP232-302

The loopback test is using 1 PC to test the RS232 serial to device server USR-TCP232-302.You can send the data with Ethernet and receive with serial port. And you also can send data with serial port and receive with Ethernet.
The loopback test of the serial to ethernet converter
Figure 1 The loopback test
Before you start to test, you should disable your wireless network connection and turn off firewall in your PC.
The loopback test of the USR-TCP232-302 02
Figure 2 Turn off the firewall and wireless network connection
Setup the IP address of your PC, we setup it as 192.168.0.201.It should be in same Net segment with USR-TCP232-302(default IP address 192.168.0.7). the subnet mask we use 255.255.255.0
The loopback test of the USR-TCP232-302,setup ip address of pc
Figure 3 Setup IP address of your PC
Connect the module like this picture.
 The loopback test of the USR-TCP232-302, connection of serial to ethernet converter
Figure 4 Connection of USR-TCP232-302
Open the USR M0 Series-V2.1.2.118.exe.click on search device
The loopback test of the USR-TCP232-302, configure tool

Figure 5 configure tool
We searched the module which IP address is 192.168.0.7.You can configure the module with the part of the red block.
The loopback test of the USR-TCP232-302, figure 6
Figure 6
Open the software USR-TCP232-TEST.exe, set the “COMSettings” and the “NetSettings” according the Figure6.
The loopback test of the USR-TCP232-302, figure 7
Figure 7
(1) If your module works as client, your PC should work as server. And if your module works as server, Your PC    should work as client.
(2) Your baudrate should be same.
(3) Client need a destination IP and Port which it is to connect.
If you configure all correctly. You can transmit data like this picture. If not, you should search In LAN again and configure the module again.
The loopback test of the USR-TCP232-302,setup ip address of pc
Figure 8 the communication is established